Fix: add missing rcu_barrier before daemon teardown
[lttng-tools.git] / src / bin / lttng-consumerd / lttng-consumerd.c
index 7ecbe7a3439a9f148719289a703da8014968357a..293654053e87ad046d4cc2716de75e1934b513f8 100644 (file)
@@ -16,7 +16,6 @@
  * 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA.
  */
 
-#define _GNU_SOURCE
 #define _LGPL_SOURCE
 #include <fcntl.h>
 #include <getopt.h>
 #include <unistd.h>
 #include <sys/mman.h>
 #include <assert.h>
-#include <config.h>
 #include <urcu/compiler.h>
 #include <ulimit.h>
 
 #include <common/defaults.h>
 #include <common/common.h>
-#include <common/consumer.h>
-#include <common/consumer-timer.h>
+#include <common/consumer/consumer.h>
+#include <common/consumer/consumer-timer.h>
 #include <common/compat/poll.h>
 #include <common/compat/getenv.h>
 #include <common/sessiond-comm/sessiond-comm.h>
@@ -101,14 +99,6 @@ static void sighandler(int sig)
                return;
        }
 
-       /*
-        * Ignore SIGPIPE because it should not stop the consumer whenever a
-        * SIGPIPE is catched through a FD operation.
-        */
-       if (sig == SIGPIPE) {
-               return;
-       }
-
        if (ctx) {
                lttng_consumer_should_exit(ctx);
        }
@@ -129,9 +119,10 @@ static int set_signal_handler(void)
                return ret;
        }
 
-       sa.sa_handler = sighandler;
        sa.sa_mask = sigset;
        sa.sa_flags = 0;
+
+       sa.sa_handler = sighandler;
        if ((ret = sigaction(SIGTERM, &sa, NULL)) < 0) {
                PERROR("sigaction");
                return ret;
@@ -142,6 +133,7 @@ static int set_signal_handler(void)
                return ret;
        }
 
+       sa.sa_handler = SIG_IGN;
        if ((ret = sigaction(SIGPIPE, &sa, NULL)) < 0) {
                PERROR("sigaction");
                return ret;
@@ -636,19 +628,26 @@ exit_init_data:
        tmp_ctx = ctx;
        ctx = NULL;
        cmm_barrier();  /* Clear ctx for signal handler. */
+       /*
+        * Wait for all pending call_rcu work to complete before tearing
+        * down data structures. call_rcu worker may be trying to
+        * perform lookups in those structures.
+        */
+       rcu_barrier();
        lttng_consumer_destroy(tmp_ctx);
        lttng_consumer_cleanup();
 
        if (health_consumerd) {
                health_app_destroy(health_consumerd);
        }
-exit_health_consumerd_cleanup:
+       /* Ensure all prior call_rcu are done. */
+       rcu_barrier();
 
-exit_options:
+       run_as_destroy_worker();
 
+exit_health_consumerd_cleanup:
+exit_options:
 exit_set_signal_handler:
-       /* Ensure all prior call_rcu are done. */
-       rcu_barrier();
 
        if (!retval) {
                exit(EXIT_SUCCESS);
This page took 0.032117 seconds and 4 git commands to generate.